Lamination & cure · Panevex agent

Lamira

Models encapsulant cure kinetics and controls lamination temperature, vacuum, pressure, and dwell in closed loop per material lot and stack-up — predicting cure state and gel content before the module exits the press.

Encapsulation cure controlwhat it does
Jetson Orin + OVXruns on
Closed-loopcontrol mode
Front glass Encapsulant (EVA/POE) Cell matrix Encapsulant (EVA/POE) Backsheet °C CURE 98.4% vacuum 6.2 mbar · dwell 12:40

Lamira — Cured right the first time — no delamination, bubbles, or cell shift.

The problem it solves

Why lamination & cure breaks without autonomy

Open-loop today

Fixed recipes can't respond when materials, temperature, or cell quality drift mid-shift.

Invisible failure

The defects that matter most are the ones no operator can see at line speed.

Lost watts & yield

Every uncorrected drift ships as lost power, rework, or a field-degradation liability.

Front glass Encapsulant (EVA/POE) Cell matrix Encapsulant (EVA/POE) Backsheet °C CURE 98.4% vacuum 6.2 mbar · dwell 12:40

How Lamira works

Models encapsulant cure kinetics and controls lamination temperature, vacuum, pressure, and dwell in closed loop per material lot and stack-up — predicting cure state and gel content before the module exits the press.

  • Perceives its station in real time with fused sensing.
  • Predicts the physical outcome before the module moves on.
  • Controls the machine in closed loop, within human-set guardrails.
  • Writes every outcome back to the shared module twin.
Capabilities

What Lamira delivers

Real-time perception

Station-specific sensing tuned for lamination & cure.

Closed-loop control

Set-points corrected on the machine with bounded latency.

Auditable actions

Every decision stores the evidence that justified it.

Yield analytics

Root-cause traces from outcome back to this station.

MES integration

Fits your existing PLCs, SCADA, and MES.

Edge-native

Runs on Jetson Orin + OVX for deterministic performance.

AttributeDetail
StationLamination & cure
Primary functionEncapsulation cure control
Runs onJetson Orin + OVX
Control modeClosed-loop, guardrailed
Data written toTwinvex module digital twin
Integrates withMES · SCADA · equipment PLCs
99.4%
Perception recall
<10 ms
Edge decision latency
24/7
Autonomous operation
3.2 W
Contributes to recovered power
In the loop

Where Lamira sits in the flywheel

Module digital twin Ribbix strings Elumnex sensing Lamira cure Binova match Twinvex simulate

One agent, one shared brain

Lamira doesn't work in isolation. It reads from and writes to the same module twin as every other agent, so its improvements compound across the whole line.

  • Shares the module digital twin
  • Learns from every run on every line
  • Policy transfers across fabs
“Lamira turned our lamination & cure station from a source of escapes into our most predictable process. It just runs.”
LAProcess EngineerTier-1 module manufacturer
Do we need the whole Panevex platform to run Lamira?
No. Lamira can deploy standalone on its station and still delivers value — though it gets stronger as more agents share the twin.
Will it work with our existing machines?
Yes. Lamira augments your current equipment through standard PLC, SCADA, and MES interfaces — no rip-and-replace.
How is the autonomy kept safe?
Every actuator has human-set guardrails. Low-confidence decisions hold within safe bounds and escalate with evidence.

See Lamira on your line

Book a walkthrough and we'll show Lamira running against your real lamination & cure data.

The autonomy stack

Every module, peak power.